A worker treating the surface of a workpiece inside a factory building

In the oil degumming stage, the foam layer rises rapidly after water is added for hydration, oil-foot settling slows, the transparency of the degummed oil fluctuates between two batches, and the distillation and filtration schedule of the refining line is pinned down at the degumming step.

Chemi Tech supplies the KM-866 series of defoamers for the oil processing and refining degumming stage; the dosage is adjusted flexibly by the acid value of the oil, the hydration water addition and the degumming temperature. This grade has excellent compatibility in the oil phase, neither separating nor clouding, causing no interference with the viscosity and oxidative stability of the oil, and the phospholipid-residue reading does not rise because of dosing. The measured data on oil-foot settling time and degummed-oil transparency are recorded side by side at the same degumming batch, and the fitted dosage of the KM-866 series is determined accordingly; the dosage of that line is set only after the oil acid value and degumming temperature are checked separately.

Advantages of Chemi Tech Defoamers

The Chemi Tech KM-866 series defoamer is configured for the oil processing and refining degumming stage. Its oil compatibility is excellent, neither separating nor clouding in the oil phase; it breaks foam fast, thinning the foam layer within a short time after hydration and stirring; its foam-suppressing duration is long-lasting, so no batch-by-batch top-up is needed in the degumming standing section; it causes no interference with the viscosity and oxidative stability of the oil, so oil-foot settling time is not extended; the phospholipid-residue reading stays stable, so degummed-oil transparency does not fall because of dosing; and the additive cost per tonne of oil is recorded along with the batch number.

Industry Pain Points and Solutions

The root of foaming in oil degumming lies mostly in the combined effect of a too-high phospholipid content in the oil foot and excessive hydration water addition, while a rising temperature in the alkali-refining section stabilises the fine bubbles inside the oil phase, finally concentrating in two places: slow oil-foot settling and insufficient degummed-oil transparency.

When the hydration water addition is too large, fine bubbles first float up at the oil-water interface and the oil-foot settling time diverges between two batches. KM-866 has excellent oil compatibility; once the two readings of acid value and water addition are cleared, its dosage is re-rated by the phospholipid content of that oil batch, and the settling time shortens accordingly.

After the temperature in the alkali-refining section rises, the same dosage performs markedly differently at the low and high grades, and the degummed-oil transparency is lower at the high grade. KM-866 is compared side by side at fifty and seventy degrees Celsius; the transparency rating rises from grade two to grade four, and the dosage is rated to the fitted grade of that line.

When the residence time after degumming lengthens, the stable period of the fine bubbles is further extended and the foam-suppressing margin is consumed step by step. KM-866 adds no extra standing time on this item; once acid value, water addition and temperature are all checked through, the refining shift maintains operation at that grade.

Typical Operating Conditions and Verification

Customer case: the refining and degumming workshop of an oil processing enterprise in Guangdong, applied to the hydration degumming stage of rapeseed oil.

At this plant the transparency of two degummed-oil batches differed markedly, the phospholipid-residue reading ran high on the high-acid-value batch, and oil-foot settling time lengthened batch by batch. KM-866 was set as the replacement solution, with the dosage rated by the oil acid value and degumming temperature. Reading changes after commissioning: the transparency of the two degummed-oil batches converged; the phospholipid-residue reading fell back into the pass range; oil-foot settling time dropped from four hours to two hours; and the feed batches of the distillation line no longer needed adjustment because of degumming fluctuations.

Frequently Asked Questions

If the KM-866 series is dosed over the long term in oil degumming, will it skew the viscosity and oxidative stability of the oil?

It is subject to two operating conditions: the degumming temperature and the hydration water addition. The KM-866 series has excellent compatibility in the oil phase, neither separating nor clouding; the measured data on oil-foot settling time and degummed-oil transparency are given side by side by Chemi Tech from two readings at the same degumming line, and dosing at the rated magnitude does not disturb the oil's own oxidative stability. The actual dosage is corrected by the phospholipid-residue reading; Chemi Tech determines the fitted dosage from the comparison of the two degumming grades.