Industrial chimneys glowing with orange fire and dense smoke against the night sky

The electronic cleaning agent foams continuously in the circulating tank, the liquid-level reading rises falsely in step, the residual liquid carried out of workpiece gaps leaves white marks after drying, and re-washing and top-up pin the shift's throughput down at the low-foam formulation step.

Chemi Tech supplies the KM-192 series of defoamers for the silicone-free low-foam system of electronic cleaning agents; the dosage is adjusted flexibly by the active-matter content of the cleaning agent, bath temperature and circulation tempo. This grade is a silicone-free system, containing no silicone oil or silicone polyether, leaving no silicone spots in silicone-banned processes and causing no interference with additive residues on the workpiece surface. The measured data on the foam-layer half-life at the bath surface and the workpiece residue rating are recorded side by side at the same cleaning tank, and the fitted dosage of the KM-192 series is determined accordingly; it is finalised only after the cleaning-agent system and workpiece material are checked in grades.

Advantages of Chemi Tech Defoamers

The Chemi Tech KM-192 series defoamer is configured for the silicone-free low-foam system of electronic cleaning agents. It is a silicone-free system, leaving no silicone spots in silicone-banned processes; it breaks foam fast, thinning the foam layer on the circulating tank within minutes; its foam-suppressing duration is long-lasting, so no shift-by-shift top-up is needed during continuous bath circulation; its compatibility is excellent, coexisting in the same tank with common cleaning active matter without disturbing detergency; its stability is strong, so the foam-layer thickness does not fluctuate as the bath temperature rises; and the chemical consumption per tank can be accounted shift by shift.

Industry Pain Points and Solutions

The root of insufficient low foaming in electronic cleaning agents lies mostly in the combined effect of a too-high active-matter content and air entrained by circulation shear, while a rising bath temperature stabilises the fine bubbles at the liquid surface, finally concentrating in two places: the falsely high liquid level and the white marks on workpieces.

When the surfactant content rises, the foam layer on the circulating tank first thickens and a deviation appears between the liquid-level reading and the gauge. KM-192 contains no silicone; once the two readings of active matter and temperature are cleared, its dosage is re-rated by the load of that tank, and the foam-layer half-life shortens accordingly.

As the bath temperature continues to rise, foam breaking and regeneration play against each other, and the liquid film carried out when the workpiece is lifted from the surface leaves marks after drying. KM-192 is compared side by side at twenty-five and forty-five degrees Celsius; the white-mark rating drops from grade three to grade one, and the dosage is rated to the fitted grade of that tank.

As the residual cleaning liquid keeps accumulating, the stable period of the foam layer is further extended and the foam-suppressing margin is consumed step by step. KM-192 adds no extra skimming frequency on this item; once active matter, temperature and residual liquid are all checked through, the fitted dosage of that tank is made clear and the cleaning shift executes at that magnitude.

Typical Operating Conditions and Verification

Customer case: the pre-filling treatment workshop of an electronic-component cleaning-agent formulator in Jiangsu, applied to the formulation stage of silicone-free low-foam electronic cleaning agents.

At this plant the foam-layer half-life of two cleaning-agent batches differed markedly, silicone-spot complaints concentrated on the precision-connector batches, and the white-mark rating ran high in the low-temperature tank section. KM-192 was dosed as the defoaming grade for that line after comparison of the two readings of active-matter content and bath temperature, with the dosage rated by circulation tempo and residual-liquid accumulation. Reading changes after commissioning: the foam-layer half-life of the two batches converged; silicone-spot complaints on the precision-connector batches no longer appeared; the white-mark rating fell from grade three to grade one; and the top-up frequency fell from twice per shift to once per day.

Frequently Asked Questions

If the KM-192 series is dosed over the long term in silicone-banned cleaning processes, will it skew the low-foam advantage of the cleaning agent?

It must be read from two clues together: the cleaning-agent active matter and the bath circulation. The KM-192 series is a silicone-free system, leaving no silicone spots in silicone-banned processes; the measured data on foam-layer half-life and workpiece white-mark rating are given side by side by Chemi Tech from two readings at the same cleaning tank, and dosing at the rated magnitude does not disturb the cleaning agent's own detergency. The actual dosage is corrected by the workpiece white-mark rating; Chemi Tech gives the fitted dosage through comparison of the two readings at the same cleaning tank.