White powder being sampled from a petri dish on a laboratory bench
On the Hegman grind gauge, the same batch of colour paste was still within spec just after sand milling, yet rebounded two gradations after standing for half a day, and rub-out floating colour showed up on the drawdown panel.
Chemi Tech supplies the KMK-201 series dispersant for the wetting and dispersion of inorganic pigments and titanium dioxide. Its binding to the pigment and extender surface is stable, fineness does not rebound after high-shear milling, and viscosity reduction is marked. The dosage can be adjusted flexibly according to pigment particle size, target solids and surface treatment; why this binding stays stable is a formulation matter and will not be expanded here, so trying it with your own material is more direct. For formulations that change grades, comparable cases can be checked grade by grade.
Advantages of Chemi Tech Dispersants
The Chemi Tech KMK-201 series dispersant is designed for inorganic pigment and titanium dioxide systems. Its binding to the pigment and extender surface is stable, so fineness stays consistent after high-shear milling; viscosity reduction is marked, so the sand mill current stays steady; its adaptability to extender pigments is wide, so a grade change does not call for a full reformulation; storage stability is strong, so the paste neither coarsens nor floats colour; fineness stability is strong, so the rub-out floating-colour rating stays consistent; and the dosage is adjusted by pigment grade and target solids.
Industry Pain Points and Solutions
When fineness keeps moving around the acceptance line, is the cause milling time or the change of pigment grade?
After a batch of titanium dioxide is changed, the dispersant that worked before may not hold on the new surface, and fineness readings rebound around the acceptance line. KMK-201 compares grades with surface treatments one by one; once the two clues are sorted, the dosage is rated grade by grade and the fineness reading stabilises.
When the target solids go up, paste viscosity pushes the sand mill current higher, milling time becomes longer, yet fineness is still not where it should be. Comparing low and high solids side by side, the sand mill current drops from eighteen amperes to twelve, and the dosage is rated to the suited grade of that colour system.
Over longer storage, coarsening and floating colour tend to show up late. With KMK-201 the binding to pigment and extender is stable, so no extra regrinding is needed; the standing record before warehousing should not be skipped, though. If coarsening appears late in storage, should the cause be looked for in the solids target again? That is left to each batch of paste to verify.
Typical Operating Conditions and Verification
Customer case: the colour paste preparation workshop of an industrial coatings enterprise in Shandong, applied to the grinding and mixing section for multiple grades of titanium dioxide and inorganic pigments.
The regrind records of the first half of the year at this plant began with one rub-out panel: the same formulation gave markedly different fineness readings at three grades, the floating-colour rating passed at only one of the grades, and the sand mill current fluctuated widely with grade. After comparing grades and solids targets, KMK-201 was selected as the dispersant grade for the workshop, with the dosage rated by surface treatment.
The regrind records kept by the workshop show that fineness readings of the three grades converged, the floating-colour ratings all fell within the passing range, the sand mill current no longer fluctuated widely with grade, and regrinding rounds decreased.
Frequently Asked Questions
Another grade of titanium dioxide is coming in next month; can one dispersant handle several grades at once?
Work out the two readings of surface treatment and target solids before discussing whether one grade can cover several. KMK-201 compares grades one by one and has wide adaptability to extender pigments; the measured data on fineness and rub-out floating-colour rating are kept by Chemi Tech for the same colour system in pigment-by-pigment comparisons. Target solids is one item used for correction; once the surface treatment and solids target of the new grade are provided, a reference dosage grade can be given first.