Stainless-steel pipework and valve assemblies densely arranged along the outer wall of the equipment
Froth in the wire pit under the forming wire keeps building up; the suction of the stock pump then entrains microbubbles, and the deviation in basis-weight fluctuation and sheet formation becomes concentrated at the rewinding stage.
Chemi Tech supplies the KM-1003 series of defoamers for the wire forming and white-water recovery sections of paper machines; the dosage is adjusted flexibly by white-water concentration, sizing-agent dosage and wire speed. This grade is silicone-free: it breaks foam fast in surface-foam systems containing rosin size, does not disturb retention and drainage or the sizing reaction, and leaves no deposits on the forming wire or the couch roll. The measured data on foam-layer height in the wire pit and the cross-direction basis-weight deviation of the sheet are set side by side, and the fitted dosage of the KM-1003 series is determined from them.
Advantages of Chemi Tech Defoamers
The Chemi Tech KM-1003 series defoamer is configured for the wire section and the white-water circulation of paper machines. As a silicone-free system it produces no silicone-spot deposits on the forming wire or the couch roll; it breaks foam fast, and the surface foam falls back visibly once the stock pump stops feeding; its foam-suppression duration is long-lasting, so no extra replenishment rounds are added when the sizing-agent dosage is raised; its compatibility is excellent, leaving retention and drainage and the sizing reaction undisturbed; the dosage is economical, graded by white-water concentration; and the foam-layer height stays stable and controllable as the wire speed is raised.
Industry Pain Points and Solutions
The root of foaming in the wire section lies mostly in the combined effect of surfactants carried in by the sizing agent and fines in the white-water circulation, while the high shear of the stock pump further stabilises microbubbles above the wire-pit surface, finally producing two problems: basis-weight fluctuation and pinholes in the sheet.
When the sizing-agent dosage runs high, the foam layer on the wire-pit surface first builds up thick, and microbubble entrainment at the stock-pump suction follows. KM-1003 is silicone-free; once the two readings of white-water concentration and sizing-agent dosage are set, its dosage is re-rated by the wire-section load, and the cross-direction basis-weight deviation narrows to within the process band.
After the wire speed is raised, the white-water circulation rises in step and foam is carried into the headbox, so the uniformity of the slice jet and the formation of the sheet decline together. KM-1003 does not lose foam-breaking power in rosin-size systems; the two sets of readings, foam-layer height in the wire pit against cross-direction basis-weight deviation, and slice-jet pressure against the finished-sheet formation index, are compared side by side, the addition is rated to the fitted grade of that machine, and formation no longer falls off roll after roll.
When white-water concentration reaches the upper limit, fines lengthen the foam lifetime and the wire-rinsing water consumption rises in step. The KM-1003 series leaves no deposits on the forming wire and adds no extra shutdown scrubbing rounds on this item; once the three readings of white-water concentration, wire speed and sizing-agent dosage are gathered, the precise dosage of that machine becomes clear and the paper-machine hall schedules its inspection records at that grade.
Typical Operating Conditions and Verification
Customer case: the paper-machine hall of a cultural-paper producer in Hebei, applied to the wire forming and white-water recovery sections.
Before the switch, foam on the wire-pit surface had long covered the overflow weir, and the cross-direction basis-weight deviation forced a readjustment of the headbox slice once every shift. After comparing white-water concentration and sizing-agent dosage, KM-1003 was dosed, with the addition rated by wire speed and foam-layer height; foam-layer height in the wire pit and cross-direction basis-weight deviation were logged by shift, and slice-jet pressure against the finished-sheet formation index formed a second side-by-side set. After the solution was in place, the cross-direction basis-weight deviation returned to within the process band; the finished-sheet formation index no longer fell roll after roll, and the forming-wire scrubbing cycle was stretched from once a week to once a fortnight.
Frequently Asked Questions
Will long-term dosing of the KM-1003 series into white water containing rosin size affect the degree of sizing?
The white-water concentration and sizing-agent dosage must be brought together to check the sizing curve of that machine. The KM-1003 series is silicone-free and does not disturb retention and drainage or the sizing reaction; the measured data on wire-pit foam-layer height and finished-sheet formation index are given by Chemi Tech from side-by-side measurement of the same wire section, and dosing at the rated magnitude does not change the original level of sizing. The actual addition is referenced to white-water concentration and wire speed, and Chemi Tech gives the fitted dosage of that machine from the side-by-side comparison.