White foam on a yellow-brown liquid surface gathering into fine dense streaks along the tank wall
After an oil change, the foam layer on the hydraulic-station reservoir keeps refusing to disperse; air entrainment at the pump suction and sluggish actuator movement follow one after another, and the servo-valve response deviation shows up sharply on the pressure curve.
Chemi Tech supplies the KM-860 series of defoamers for hydraulic-station oil circulation and oil-change maintenance; the dosage is adjusted flexibly by oil viscosity, system pressure and reservoir turnover rate. This grade has excellent compatibility in mineral-based hydraulic oil, breaks foam fast without separating out, does not compete with anti-wear additives for adsorption sites, and disturbs neither the demulsibility nor the filterability of the oil. The measured data on reservoir foam-layer height and return-filter pressure drop are read side by side, and the optimal dosage of the KM-860 series is fixed from these two sets of readings.
Advantages of Chemi Tech Defoamers
The Chemi Tech KM-860 series defoamer is configured for hydraulic-station reservoirs and return-filtration stations. Its compatibility is excellent, with no separation in mineral-based oil; defoaming is fast, and the surface foam falls back markedly after the pump set stops; foam suppression is long-lasting, so no extra dosing rounds are added when system pressure is raised; it does not compete for anti-wear additive adsorption sites, so oil-film strength is unchanged by dosing; the dosage is economical, rated in steps by oil viscosity; and filterability stays stable, giving the return-filter pressure drop the conditions for a longer replacement cycle.
Industry Pain Points and Solutions
The root of foaming in hydraulic oil lies mostly in the combined effect of air mixed in during the oil change and the shift in oil viscosity, while the shear of high-pressure return oil further stabilises the micro-bubbles at the reservoir surface, finally producing two problems: air entrainment at the pump suction and sluggish actuator response.
When oil viscosity runs low, a fine foam first appears on the reservoir surface and the vacuum reading at the pump suction fluctuates with it. KM-860 has excellent compatibility; once the oil-viscosity and system-pressure readings are set, its dosage is re-rated by reservoir volume, and the suction vacuum returns to the set range.
After system pressure is raised, return-oil velocity and air entrainment rise in step, and the filter pressure drop and servo-valve response time climb together. KM-860 loses no foam-breaking speed in mineral-based oil; by comparing the two sets of readings, reservoir foam-layer height against return-filter pressure drop, and pump-outlet pressure ripple against servo-valve response time, the dosage is rated to the fitted grade of that station, and the pressure curve no longer shows burrs shift after shift.
When the turnover rate is pushed to its upper limit, the micro-bubbles have no time to dissipate in the reservoir and the demulsibility of the oil falls in step. The KM-860 series does not compete with anti-wear additives for adsorption sites and adds no extra oil-retest rounds on this item; once the three readings of oil viscosity, system pressure and turnover rate are brought together, the fitted dosage of that station is settled and the equipment department draws up the oil-change ledger at that grade.
Typical Operating Conditions and Verification
Customer case: the hydraulic test station of a construction-machinery manufacturer in Jiangxi, applied to the pump-set circulation and return-filtration stages.
Before the switch, foam in the reservoir after an oil change often overflowed the level gauge and the servo valve had to be recalibrated once per shift. KM-860 was selected for this class of hydraulic station, with the dosage rated by oil viscosity and system pressure; the reservoir foam-layer height and return-filter pressure drop were logged per shift, and the pump-outlet pressure ripple and servo-valve response time were compared as a separate set. After the programme was in place, the suction vacuum returned to the set range; the servo-valve response was no longer sluggish shift after shift, and the return-filter replacement cycle stretched from once a month to once every two months.
Frequently Asked Questions
Will long-term dosing of the KM-860 series in a high-pressure hydraulic system affect the demulsibility of the oil?
What directly decides this item is whether the oil viscosity and turnover rate fall within the filtration margin of that station. The KM-860 series does not compete with anti-wear additives for adsorption sites; the measured data on reservoir foam-layer height and return-filter pressure drop are given by Chemi Tech from side-by-side measurements on the same oil station, and dosing at the rated magnitude does not change the oil's original demulsification rhythm. The field dosage is weighed separately against system pressure, and Chemi Tech fixes the fitted magnitude of that station from the side-by-side comparison.