Circular tanks and screens of a wastewater treatment plant arranged in groups as seen from above

Once a thick layer of foam builds up on the surface of a municipal wastewater bioreactor, oxygen-transfer efficiency drops markedly, the suspended solids and chemical oxygen demand of the secondary-settling-tank effluent rise together, the sludge settling ratio climbs in step, and the environmental on-line instrument is the first to report an out-of-limit reading.

Chemi Tech has introduced the KM-1200 series of defoamers for the bioreactor and the aeration stage of the secondary settling tank in municipal wastewater; the dosage is adjusted flexibly by influent chemical oxygen demand, aeration rate and sludge concentration. This grade is non-toxic, harmless and environmentally degradable, does not affect the nitrification ability of activated sludge, and forms no scale and no blockage on membrane modules or diffusers. Once the measured data on the foam-layer thickness on the tank surface and the suspended solids in the secondary-settling-tank effluent are checked together, the dosing grades are set separately for different influent loads.

Advantages of Chemi Tech Defoamers

The Chemi Tech KM-1200 series defoamer is configured for the bioreactor and secondary settling tank of municipal wastewater. It does not affect activated-sludge activity, and the sludge settling ratio and microscopic-examination results stay stable; it resists high salinity, and the foam-breaking speed does not decay in pool sections with high salt content; it forms no scale and no blockage on membrane modules or diffusers, and the flux decline under long-term operation stays within a controllable range; and the dosage is economical, rated by influent load, so the chemical cost per tonne of water can be accounted month by month.

Industry Pain Points and Solutions

The root of foaming in the bioreactor lies mostly in the combined effect of residual surfactants in the influent and aeration shear, while at a long sludge age the polysaccharides released by aged sludge further stabilise the foam on the tank surface, finally concentrating in two places: the foam layer on the tank surface and the secondary-settling-tank effluent.

When the influent chemical oxygen demand climbs to the upper design limit, the foam in the aeration tank first covers the tank surface, the oxygen-transfer efficiency falls in step, and the ammonia-nitrogen removal rate of the aerobic section drops together. KM-1200 does not affect sludge activity; once the two readings of influent load and aeration rate are cleared, the dosage is re-rated by the surface state of the tank, and the foam-layer thickness narrows to an observable low grade.

After the aeration intensity is raised, the foam layer thickens continuously with the agitation, and sludge loss and effluent suspended solids in the secondary settling tank rise together. KM-1200 resists high salinity and breaks foam fast; with the two sets of readings, foam-layer thickness on the tank surface against suspended solids in the secondary-settling-tank effluent, compared together, the addition is rated to the fitted grade of that station, and the effluent suspended solids fall back within the pass range of the on-line instrument.

Scaling on membrane modules and diffuser plates is also included in the check; KM-1200 is silicone-free and adds no extra cleaning frequency on this item; once the three readings of influent, aeration and sludge are checked through, the fitted dosage of that station is made clear and the wastewater station doses by the rated magnitude.

Typical Operating Conditions and Verification

Customer case: a municipal wastewater treatment operator in Hebei, applied to the aeration defoaming stage of the bioreactor and secondary settling tank.

The influent chemical oxygen demand ran up to the upper design limit, the foam layer on the tank surface covered nearly half the tank, and the suspended solids of the secondary-settling-tank effluent crossed the line for two shifts running. After comparison against influent load and aeration rate, KM-1200 was dosed, with the addition rated by sludge concentration and water temperature; the plant logged the two sets of readings, foam-layer thickness on the tank surface and suspended solids in the secondary-settling-tank effluent, into the same shift report. After the solution was in place, the foam layer on the tank surface thinned, the suspended solids of the secondary-settling-tank effluent returned to the pass range of the on-line instrument, the diffuser-plate cleaning cycle was stretched from once a week to once a fortnight, and the ammonia-nitrogen removal rate of the aerobic section no longer fluctuated with the foam layer.

Frequently Asked Questions

Will long-term dosing of a defoamer into the bioreactor throw the sludge activity off course?

It depends on whether the concentration of residual surfactants in the influent and the aeration intensity fall within the same assessment grade. The KM-1200 series does not affect activated-sludge activity; the measured data on sludge settling ratio and effluent chemical oxygen demand are given by Chemi Tech after controlled side-by-side measurement of the same tank section, and dosing at the rated magnitude does not disturb the original pace of nitrification and denitrification. The actual addition is corrected by the influent load and sludge settling ratio of the shift, and Chemi Tech determines the precise dosage of that station from the controlled side-by-side data of the same tank section.