A scraper truss crossing a brown liquid surface diagonally over the tank

Once a thick layer of foam builds up on the aeration tank of a printing-and-dyeing wastewater treatment station, the suspended solids in the secondary-settling-tank effluent and the sludge settling ratio rise together, the ammonia-nitrogen removal rate of the aerobic stage falls in step, and the environmental on-line data crosses the line first at this stage.

Chemi Tech supplies the KM-1202 series of defoamers for the aeration stage and the bioreactor of printing-and-dyeing wastewater treatment stations; the dosage is adjusted flexibly by influent chemical oxygen demand (COD), air-blower rate and sludge age. This grade is environmentally degradable, does not affect activated-sludge activity, and forms no scale and no blockage on membrane modules or diffusers. The measured data on the foam-layer thickness on the tank surface and the suspended solids in the secondary-settling-tank effluent are checked together, and the fitted dosage of the KM-1202 series is given directly by these two sets of readings.

Advantages of Chemi Tech Defoamers

The Chemi Tech KM-1202 series defoamer is configured for the aeration stage and the bioreactor of printing-and-dyeing wastewater treatment stations. It is environmentally degradable, and the effluent chemical oxygen demand is not raised by the dosing; it does not affect activated-sludge activity, and the sludge settling ratio stays stable; it resists high salinity, and the foam-breaking speed does not decay in pool sections with high salt content; it forms no scale and no blockage on membrane modules or diffusers, and the flux decline stays controllable; and the dosage is economical, rated by the influent load, so the chemical cost per tonne of water can be accounted directly.

Industry Pain Points and Solutions

The root of the surface foam at the aeration stage lies mostly in the combined effect of surfactants carried in by desizing effluent and aeration shear, while at a long sludge age the extracellular polysaccharides released by aged sludge further stabilise the bubbles on the tank surface, finally concentrating in two places: the foam-layer thickness and the suspended solids in the secondary-settling-tank effluent.

When desizing effluent is discharged in a concentrated surge, the foam in the aeration tank first covers the tank surface, the oxygen-transfer efficiency falls in step, and the ammonia-nitrogen removal rate drops together. KM-1202 does not affect activated-sludge activity; once the influent chemical oxygen demand and air-blower rate readings are cleared, the dosage is re-rated by the surface state of the tank, and the foam-layer thickness narrows to a low grade.

After the air-blower rate is turned up, the foam layer thickens with agitation, and sludge loss and effluent suspended solids in the secondary settling tank rise together. KM-1202 resists high salinity and breaks foam fast; with the two aeration grades of 0.8 and 1.1 cubic metres per tonne laid side by side and the two sets of effluent suspended-solids readings of 42 milligrams per litre and 19 milligrams per litre compared in step, the dosage is rated to the fitted grade of that tank, and the effluent suspended solids fall back within the pass range.

After the sludge age is extended, the polysaccharides released by aged sludge stabilise the foam on the tank surface and the state of the zoogloea under microscopic examination changes in step. The KM-1202 series introduces no silicone deposition, and membrane-module cleaning stays on the original schedule; once the influent load, air-blower rate and sludge age readings are all checked through, the fitted dosage of that tank is made clear and the wastewater station doses at that magnitude.

Typical Operating Conditions and Verification

Customer case: the wastewater treatment station of a printing-and-dyeing enterprise in Shandong, applied to foam control at the aeration stage and in the bioreactor.

The influent load ran at the design upper limit for two consecutive shifts, the foam layer spread across half the aeration tank, the effluent suspended solids of the secondary settling tank crossed the line twice, and when the diffuser plate was pulled and inspected a layer of slime was found attached to its face. After comparison against influent chemical oxygen demand and air-blower rate, KM-1202 was dosed, with the dosage rated by sludge concentration and water temperature; the plant recorded the two sets of readings of foam-layer thickness and effluent suspended solids side by side in the shift report. After the switch, the foam layer on the tank surface thinned to the point where it no longer overtopped the scraper truss, the effluent suspended solids returned to the pass range, and the ammonia-nitrogen removal rate and the sludge settling ratio both returned within the design band.

Frequently Asked Questions

Will long-term dosing of a defoamer into the bioreactor throw the sludge activity and effluent indicators off course?

Work out how much each of the two readings of influent chemical oxygen demand and air-blower rate has enlarged the foam layer before deciding how much defoamer to dose into the aeration stage. The KM-1202 series does not affect activated-sludge activity; the measured data on the sludge settling ratio and the effluent chemical oxygen demand are checked side by side by Chemi Tech for the same pool section, and dosing at the rated magnitude does not disturb the original pace of nitrification and denitrification. The actual dosage is corrected by the influent load and air-blower rate of the shift; Chemi Tech gives the fitted dosage from the side-by-side measurement of the aeration stage and the bioreactor.